Smoke alarm laws in the ACTHardwired since 1994, linked on every level.

Working smoke alarms are compulsory in the ACT. Houses built after 1 November 1994 must have hardwired alarms, and a hardwired alarm can only be replaced with another hardwired one, which is a licensed electrician's job. In a home with more than one level, ACT Fire & Rescue says there must be an alarm on each level and they must be interconnected.

Updated 29 October 2026 · Written by the Sparky Next Door team · How we check our facts

Which side of 1994 is your house on?

The date that matters in Canberra is 1 November 1994. Houses built after it are legally required to have hardwired alarms, which run on the home's power and keep a backup battery for blackouts. Older houses still need working alarms, but the hardwired requirement is tied to that date.

If yours are hardwired now, they stay that way. ACT Fire & Rescue says a hardwired alarm must be replaced with a hardwired alarm, and connecting one to the home's power is licensed electrical work.

Homes with more than one level

A multi-level home needs an alarm on each level, interconnected. Linked alarms talk to each other, so smoke in a downstairs living room also sets off the alarm outside the upstairs bedrooms.

ACT Fire & Rescue's wider advice is hardwired, interconnected alarms wherever possible. Where a battery alarm is used, it rates a photoelectric alarm with a 10-year lithium battery as the best option.

Renting in the ACT: who does what

LandlordTenant
When the tenancy startsMakes sure working smoke alarms are installed, complying with AS 3786Moves in with working alarms
During the tenancyDoes urgent repairs, such as a dangerous electrical fault, as soon as practicableChecks the alarms and replaces the battery
A hardwired alarm failsArranges a licensed electrician, replacing hardwired with hardwiredTells the landlord rather than swapping it

Selling in the ACT: a gap we're upfront about

We couldn't find an official ACT page setting out smoke alarm rules when a home is sold, so we don't state any. If you're selling, ask your conveyancer what the contract needs, and have every alarm tested and its date checked either way.

What to ask the electrician

  • Which licence do you hold, and can I find you on Access Canberra's public register of electricians?
  • Can I see a certificate of currency for your public liability insurance?
  • Will the replacements be hardwired photoelectric alarms that all sound together?
  • Will you lodge the certificate of electrical safety form and give me a copy?
  • When were these alarms made, and when are they due for replacement?

What you can do, and what's licensed work

You can

  • Test the alarms and change the battery, which is the tenant's job in a rental.
  • Vacuum the dust off each alarm every six months, as ACT Fire & Rescue advises.
  • Replace a removable lead or alkaline battery every 12 months. ACT Fire & Rescue suggests the end of daylight saving as the reminder.

Leave to a licensed electrician

  • Replacing a hardwired alarm, always with another hardwired one.
  • Interconnecting alarms across levels.
  • Any electrical wiring work, which must meet the wiring rules and be tested to AS/NZS 3017.

What we'd do in Canberra

Check your home's build date and count the levels. If the alarms are near 10 years old, aren't photoelectric, or don't sound together across floors, get a licensed electrician to fit hardwired photoelectric alarms that are interconnected, and ask for a copy of the certificate form. Then set a reminder for 10 years from the date on the sticker, because ACT Fire & Rescue says to replace alarms every 10 years whatever powers them.

Want a specialist to sort it?

Tell us the job and your postcode. We match the licence-checked local electrician who does this kind of work, and they call you. No ring-around, and your number goes to them alone.

Get matched

Questions

Straight answers.

Do I need photoelectric alarms in the ACT?

ACT Fire & Rescue encourages replacing older alarms with photoelectric ones, especially an ionisation alarm that's faulty or close to its expiry date. We haven't seen an ACT rule that requires the photoelectric type, so treat it as strong advice.

Who replaces the battery in an ACT rental?

The tenant. The landlord's duty is to make sure working alarms are in place when the tenancy starts, and every rental must have an alarm that complies with AS 3786.

My house was built before 1994. Can I use battery alarms?

The hardwired requirement applies to ACT houses built after 1 November 1994. For older houses, what we've confirmed is that working alarms are compulsory. ACT Fire & Rescue still recommends hardwired, interconnected alarms wherever you can manage it.